{"title":"HFC","description":"","products":[{"product_id":"r407c","title":"R407C","description":"\u003ch3\u003eR407C Refrigerant (HFC Blend for Commercial HVAC\u0026amp;R)\u003c\/h3\u003e\n\u003cp\u003eR407C is a zeotropic HFC blend (R32\/R125\/R134a) with a temperature glide, specifically developed as a replacement for R22. With zero Ozone Depletion Potential (ODP), it offers a cost-effective and reliable solution for both new equipment and retrofit applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 98.6266%; height: 230.173px;\" height=\"43\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5833px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3403px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3403px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3403px;\"\u003e86.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5833px;\"\u003e-43.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5833px;\"\u003e187\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5833px;\"\u003e672.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"112\" style=\"height: 17pt; width: 56.7778%;\"\u003e99.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"125\" style=\"height: 17pt; width: 56.7778%;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"120\" style=\"height: 17pt; width: 56.7778%;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"158\" style=\"height: 17pt; width: 56.7778%;\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5833px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5833px;\"\u003e1770\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eCommercial refrigeration systems\u003cbr\u003eCentralized HVAC plants\u003cbr\u003eChillers \u0026amp; process cooling equipment\u003cbr\u003eIndustrial cold rooms\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003eNot recommended for automotive applications\u003c\/p\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":43981189742707,"sku":"HFC-R407C","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/407C.jpg?v=1761727136"},{"product_id":"r404a","title":"R404A","description":"\u003ch3\u003eR404A Refrigerant (High-Performance Solution for Commercial Refrigeration)\u003c\/h3\u003e\n\u003cp\u003eR404A is a colorless, odorless HFC refrigerant suitable for new installations and retrofit applications. With a boiling point of -46.1°C, it delivers reliable performance across critical temperature ranges.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 98.6266%; height: 242.516px;\" height=\"43\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3281px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3281px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3281px;\"\u003e97.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-51.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e162.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e548.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"112\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e99.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"125\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"120\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"158\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e3920\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eSupermarket refrigerated display cases\u003cbr\u003eCommercial cold storage facilities\u003cbr\u003eRefrigerated transport systems\u003cbr\u003eIndustrial ice-making equipment\u003cbr\u003e\u003c\/p\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":43981207666803,"sku":"HFC-R404A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/404a.jpg?v=1761726863"},{"product_id":"r134a","title":"R134A","description":"\u003ch3\u003eR134A Refrigerant (Next-Generation Eco-Friendly Refrigerant)\u003c\/h3\u003e\n\u003cp\u003eR134A is an environmentally responsible refrigerant with zero Ozone Depletion Potential (ODP), making it non-destructive to the ozone layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable height=\"43\" style=\"width: 98.6266%; height: 242.438px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3125px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3125px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3125px;\"\u003e102.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-14.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e213.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e588.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6406px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6406px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd style=\"height: 22.6406px; width: 56.7778%;\" width=\"112\" height=\"22\" class=\"et2\"\u003e99.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6406px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6406px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6406px; width: 56.7778%;\" width=\"125\" height=\"22\" class=\"et2\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6406px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6406px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6406px; width: 56.7778%;\" width=\"120\" height=\"22\" class=\"et2\"\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6406px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6406px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6406px; width: 56.7778%;\" width=\"158\" height=\"22\" class=\"et2\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e1430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Advantages:\u003cbr\u003e\u003c\/strong\u003e1. Chlorine-Free \u0026amp; Eco-Safe: Contains no chlorine atoms, eliminating ozone layer damage.\u003cbr\u003e2. Inherent Safety: Features five critical safety properties: non-flammable, non-explosive, non-toxic, non-irritating, and non-corrosive.\u003cbr\u003e3. Enhanced Performance \u0026amp; Compatibility:\u003cbr\u003e   -Delivers superior heat transfer performance compared to R12, significantly reducing refrigerant charge requirements.\u003cbr\u003e   -Maintains similar thermodynamic properties to R12, enabling straightforward system retrofits.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eAutomotive air conditioners (its most common use)\u003cbr\u003eDomestic refrigerators and freezers\u003cbr\u003eCommercial refrigeration systems\u003cbr\u003eStationary building chillers\u003cbr\u003e\u003c\/p\u003e","brand":"Nycoolmate","offers":[{"title":"Default Title","offer_id":44018841518195,"sku":"HFC-R134A-AUTO","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/R134A.jpg?v=1761727308"},{"product_id":"r32","title":"R32","description":"\u003ch3\u003eR32 Refrigerant (Ultra-Low GWP Successor to R410A)\u003c\/h3\u003e\n\u003cp\u003eR32 is a next-generation single-component HFC refrigerant with zero ODP and ultra-low GWP (GWP=675) – 70% lower than R410A. Designed as the sustainable upgrade for R410A systems, it delivers 10-15% higher energy efficiency while enabling 30% refrigerant charge reduction in compliant A2L equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003cbr\u003e\u003c\/strong\u003eMinimal temperature glide (\u0026lt;0.5°C) ensures precise temperature control\u003cbr\u003eA2L safety classification (low flammability) with ISO 5149 compliance\u003cbr\u003eDirect retrofit compatibility with R410A infrastructure (after purge\/flush)\u003cbr\u003eHydrolysis-resistant formulation (moisture ≤0.001%) prevents acid formation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable height=\"43\" style=\"width: 98.6266%; height: 242.438px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3125px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3125px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3125px;\"\u003e50.02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-61.06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e173.12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e846.17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6406px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6406px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd style=\"height: 22.6406px; width: 56.7778%;\" width=\"112\" height=\"22\" class=\"et2\"\u003e99.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6406px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6406px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6406px; width: 56.7778%;\" width=\"125\" height=\"22\" class=\"et2\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6406px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6406px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6406px; width: 56.7778%;\" width=\"120\" height=\"22\" class=\"et2\"\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6406px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6406px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6406px; width: 56.7778%;\" width=\"158\" height=\"22\" class=\"et2\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e675\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eInverter-driven residential AC (Daikin, Mitsubishi Electric)\u003cbr\u003eVRF\/VRV systems with A2L certification\u003cbr\u003eCommercial rooftop units (UL 60335-2-40 compliant)\u003cbr\u003eAir-to-water heat pumps (EN378 compliant)\u003cbr\u003eNew-generation chillers (ASHRAE 34 compatible)\u003cbr\u003e\u003c\/p\u003e","brand":"Nycoolmate","offers":[{"title":"Default Title","offer_id":44018888999027,"sku":"HFC-R32","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/R32.jpg?v=1761727283"},{"product_id":"r407a","title":"R407A","description":"\u003ch3\u003eHFC-R407A Refrigerant (Low-GWP Retrofit Solution for R404A\/R22)\u003c\/h3\u003e\n\u003cp\u003eHFC-R407A is a near-azeotropic HFC blend (R32\/R125\/R134a) designed as a low-glide, drop-in replacement for R404A and R22 in medium-temperature refrigeration systems. With zero ODP and a 30% reduced GWP (GWP≈2100) versus R404A, it complies with global phasedown regulations while maintaining comparable cooling capacity and operational performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Technical Advantages:\u003cbr\u003e\u003c\/strong\u003eOptimized temperature glide (\u0026lt;5°C) minimizes system adjustment requirements\u003cbr\u003eNear-identical operating pressure to R404A simplifies retrofit process\u003cbr\u003ePOE oil compatibility eliminates oil change requirements in most conversions\u003cbr\u003eNon-flammable (ASHRAE A1 classification) for unrestricted application\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable height=\"43\" style=\"width: 98.6266%; height: 242.516px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3281px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3281px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3281px;\"\u003e90.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-49.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e180.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e658.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"112\" height=\"22\" class=\"et2\"\u003e99.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"125\" height=\"22\" class=\"et2\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"120\" height=\"22\" class=\"et2\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"158\" height=\"22\" class=\"et2\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e2110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eMedium-temperature commercial refrigeration (supermarket cases, walk-in coolers)\u003cbr\u003eRetrofitted R404A\/R22 systems (direct drop-in per AHRI Guidelines)\u003cbr\u003eIndustrial process cooling\u003cbr\u003eTransport refrigeration units\u003cbr\u003eIce machines and cold storage units\u003cbr\u003e\u003c\/p\u003e","brand":"Nycoolmate","offers":[{"title":"Default Title","offer_id":44018895061107,"sku":"HFC-R407A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/407A.jpg?v=1761726891"},{"product_id":"r410a","title":"R410A","description":"\u003ch3\u003eR410A Refrigerant (High-Performance HFC Replacement for R22)\u003c\/h3\u003e\n\u003cp\u003eR410A is a near-azeotropic HFC blend with zero ODP (Ozone Depletion Potential), making it an ozone-safe solution. As the industry-standard replacement for R22 in air conditioning systems, it delivers ~5-6% higher refrigeration capacity and operates at higher pressures for improved efficiency.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Technical Advantages:\u003cbr\u003e\u003c\/strong\u003eMinimal temperature glide (\u0026lt;0.2°C) ensures stable system operation\u003cbr\u003ePressure-tolerant formulation maintains physical properties during leakage events\u003cbr\u003eRecharge-friendly: No need to fully evacuate system before replenishing\u003cbr\u003eCorrosion-inhibiting design (moisture ≤0.001%)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 98.6266%; height: 242.516px;\" height=\"43\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3281px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3281px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3281px;\"\u003e72.58\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-60.84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e161.83\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e691.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"112\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e99.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"125\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"120\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"158\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e2088\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eVariable refrigerant flow (VRF) systems\u003cbr\u003eDucted and ductless residential AC\u003cbr\u003eLight commercial rooftop units\u003cbr\u003eAir-to-water heat pumps\u003cbr\u003e\u003c\/p\u003e","brand":"Nycoolmate","offers":[{"title":"Default Title","offer_id":44018902532211,"sku":"HFC-R410A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/410A.jpg?v=1761727252"},{"product_id":"r422b","title":"R422B","description":"\u003ch3\u003eHFC-R422B Refrigerant (Drop-in Replacement for R22 Systems)\u003c\/h3\u003e\n\u003cp\u003eHFC-R422B is a zeotropic HFC blend specifically formulated as a direct drop-in replacement for R22 in existing refrigeration systems. With zero ODP (Ozone Depletion Potential) and a GWP of 2,539, it provides an environmentally improved alternative while maintaining similar operating characteristics to R22, requiring minimal system modifications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Technical Advantages:\u003cbr\u003e\u003c\/strong\u003eNear-identical operating pressure to R22 enables seamless retrofit\u003cbr\u003ePOE oil compatible - can be used with existing mineral oil in many systems\u003cbr\u003eNon-flammable formulation (ASHRAE A1 safety classification)\u003cbr\u003eWide temperature application range (-50°C to +10°C evaporating temperature)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable height=\"43\" style=\"width: 98.6266%; height: 242.516px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3281px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3281px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3281px;\"\u003e108.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-42.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e181.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e574.75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"112\" height=\"22\" class=\"et2\"\u003e99.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"125\" height=\"22\" class=\"et2\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"120\" height=\"22\" class=\"et2\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"158\" height=\"22\" class=\"et2\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e2526\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eDirect expansion refrigeration systems (retrofitted R22 systems)\u003cbr\u003eCommercial refrigeration systems (walk-in coolers, display cases)\u003cbr\u003eIndustrial process cooling systems\u003cbr\u003eTransport refrigeration units\u003cbr\u003eIce making machines\u003cbr\u003e\u003c\/p\u003e","brand":"Nycoolmate","offers":[{"title":"Default Title","offer_id":44018916753523,"sku":"HFC-R422B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/a3ea2c78f4f24bb87ce2906fd50f295_456ed8fb-fb0d-486d-b790-eb167cf80532.jpg?v=1763540842"},{"product_id":"r422d","title":"R422D","description":"\u003ch3\u003eHFC-R422D Refrigerant (High-Capacity R22 Replacement Solution)\u003c\/h3\u003e\n\u003cp\u003eHFC-R422D is a non-ozone depleting HFC blend specifically formulated as a high-capacity retrofit solution for R22 in commercial refrigeration systems. With zero ODP (Ozone Depletion Potential) and a GWP of 2,729, it provides an environmentally responsible alternative while delivering 5-10% higher cooling capacity compared to R22 in most medium-temperature applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Technical Advantages:\u003cbr\u003e\u003c\/strong\u003eEnhanced cooling capacity reduces compressor runtime and energy consumption\u003cbr\u003eNear-azeotropic behavior (\u0026lt;3°C glide) ensures stable system operation\u003cbr\u003eDirect drop-in compatibility with most R22 systems using POE oil\u003cbr\u003eNon-flammable formulation (ASHRAE A1 safety classification)\u003cbr\u003eWide operating range (-30°C to +10°C evaporating temperature)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable height=\"43\" style=\"width: 98.6266%; height: 242.438px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3125px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3125px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3125px;\"\u003e109.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-45.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e175.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e565.64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6406px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6406px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd style=\"height: 22.6406px; width: 56.7778%;\" width=\"112\" height=\"22\" class=\"et2\"\u003e99.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6406px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6406px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6406px; width: 56.7778%;\" width=\"125\" height=\"22\" class=\"et2\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6406px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6406px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6406px; width: 56.7778%;\" width=\"120\" height=\"22\" class=\"et2\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6406px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6406px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6406px; width: 56.7778%;\" width=\"158\" height=\"22\" class=\"et2\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e2729\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eSupermarket refrigeration systems (display cases, walk-in coolers)\u003cbr\u003eCommercial cold storage facilities\u003cbr\u003eR22 retrofit applications (direct replacement)\u003cbr\u003eIndustrial process cooling systems\u003cbr\u003eTransport refrigeration units\u003cbr\u003e\u003c\/p\u003e","brand":"Nycoolmate","offers":[{"title":"Default Title","offer_id":44018931138675,"sku":"HFC-R422D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/358367c0581e0cbfc9e6192e1071f7d_ceda68a6-4ab2-4134-aac6-52d237c1b97e.jpg?v=1763540708"},{"product_id":"r427a","title":"R427A","description":"\u003ch3\u003eHFC-R427A Refrigerant (Zero ODP Drop-in Replacement for R22 Systems)\u003c\/h3\u003e\n\u003cp\u003eHFC-R427A is a non-ozone depleting, near-azeotropic refrigerant blend designed as a direct retrofit solution for R22 in existing air conditioning and refrigeration systems. With zero ODP (Ozone Depletion Potential) and a significantly reduced GWP of 2,130 (compared to R22's GWP of 1,810), it provides an environmentally responsible alternative that requires minimal system modifications while maintaining comparable performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Technical Advantages:\u003cbr\u003e\u003c\/strong\u003eExcellent capacity matching (95-100% of R22 capacity) minimizes system reengineering\u003cbr\u003eLow temperature glide (\u0026lt;4°C) ensures stable operation and easy troubleshooting\u003cbr\u003eDirect drop-in replacement for most R22 systems with POE lubricants\u003cbr\u003eA1 safety classification (non-flammable, non-toxic) per ASHRAE Standard 34\u003cbr\u003eGood material compatibility with common metals and elastomers\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 98.6266%; height: 242.516px;\" height=\"43\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3281px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3281px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3281px;\"\u003e90.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-44.86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e188.24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e594.65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"112\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e99.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"125\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"120\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"158\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e2107\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eR22 retrofit in air conditioning systems (residential and commercial)\u003cbr\u003eCommercial refrigeration systems (walk-in coolers, display cases)\u003cbr\u003eIndustrial cooling processes\u003cbr\u003eHeat pump systems\u003cbr\u003eTransport refrigeration\u003cbr\u003e\u003c\/p\u003e","brand":"Nycoolmate","offers":[{"title":"Default Title","offer_id":44018936873075,"sku":"HFC-R427A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/a3b5a57f519e70227af39ea7ea8a090_b93dcd23-027b-4d22-aa20-9991a0919fc6.jpg?v=1763540617"},{"product_id":"r438a","title":"R438A","description":"\u003ch3\u003eHFC-R438A Refrigerant (MO29™; Long-Term R22 Retrofit Solution)\u003c\/h3\u003e\n\u003cp\u003eHFC-R438A is a non-ozone depleting zeotropic blend specifically developed as a near-drop-in replacement for R22 in existing air conditioning and refrigeration systems. With zero ODP and a moderate GWP of 2,264, it offers a balanced solution for phasing out R22 without major system modifications. Its composition is designed to closely match R22's operating pressure and capacity while maintaining compatibility with both mineral oil and POE lubricants.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Technical Advantages:\u003cbr\u003e\u003c\/strong\u003eExcellent pressure and capacity match to R22 (within ±5%)\u003cbr\u003eUnique lubricant compatibility - works with existing mineral oil or POE\u003cbr\u003eLow temperature glide (\u0026lt;7°C) for stable system operation\u003cbr\u003eA1 safety classification (non-flammable) per ASHRAE Standard 34\u003cbr\u003eReduced discharge temperature extends compressor life\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable height=\"43\" style=\"width: 98.6266%; height: 242.516px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3281px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3281px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3281px;\"\u003e99.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-44.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e185.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e623.66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"112\" height=\"22\" class=\"et2\"\u003e99.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"125\" height=\"22\" class=\"et2\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"120\" height=\"22\" class=\"et2\"\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"158\" height=\"22\" class=\"et2\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e2037\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eDirect R22 replacement in AC systems (residential and commercial)\u003cbr\u003eCommercial refrigeration retrofit (supermarkets, cold storage)\u003cbr\u003eIndustrial process cooling systems\u003cbr\u003eHeat pumps and chillers\u003cbr\u003eTransport refrigeration units\u003cbr\u003e\u003c\/p\u003e","brand":"Nycoolmate","offers":[{"title":"Default Title","offer_id":44018945556595,"sku":"HFC-R438A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/dd7c65c81af00db4aa96de9b1453460_e1920451-c45c-4c98-ada8-02e184d1d988.jpg?v=1763540545"},{"product_id":"r453a","title":"R453A","description":"\u003ch3\u003eHFC-R453A Refrigerant (R454B; Low-GWP R410A Alternative with A2L Classification)\u003c\/h3\u003e\n\u003cp\u003eHFC-R453A is a mildly flammable, low-global warming potential (GWP) refrigerant blend designed as a next-generation alternative to R410A in new air conditioning and heat pump applications. With a significantly reduced GWP of 465 (approximately 78% lower than R410A) and zero ODP, it offers an environmentally sustainable solution aligned with global regulatory phase-down schedules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Technical Advantages:\u003cbr\u003e\u003c\/strong\u003eUltra-low GWP (465) meets stringent environmental regulations\u003cbr\u003eSimilar cooling capacity to R410A (within -5% to +5% range)\u003cbr\u003eLower discharge temperatures enhance compressor reliability\u003cbr\u003eMildly flammable (A2L) classification with proven safety track record\u003cbr\u003eReduced direct emissions impact compared to HFC alternatives\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 98.6266%; height: 242.516px;\" height=\"43\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3281px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3281px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3281px;\"\u003e88.78\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-43.96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e191.48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e665.59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"112\" style=\"height: 22.6562px; width: 56.7778%;\"\u003eNot Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"125\" style=\"height: 22.6562px; width: 56.7778%;\"\u003eNot Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"120\" style=\"height: 22.6562px; width: 56.7778%;\"\u003eNot Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"158\" style=\"height: 22.6562px; width: 56.7778%;\"\u003eNot Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e1486\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eNew residential and commercial AC systems\u003cbr\u003eAir-to-water heat pumps\u003cbr\u003eVariable refrigerant flow (VRF) systems\u003cbr\u003eRooftop packaged units\u003cbr\u003eSpecialty cooling applications\u003cbr\u003e\u003c\/p\u003e","brand":"Nycoolmate","offers":[{"title":"Default Title","offer_id":44018958565491,"sku":"HFC-R453A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/901d8b2410e712396ef77b454998d5a_de2a058c-127b-4f32-b91d-1417a75d3ed5.jpg?v=1763540479"},{"product_id":"r507a","title":"R507A","description":"\u003ch3\u003eHFC-R507A Refrigerant (High-Performance Azeotropic Replacement for R502)\u003c\/h3\u003e\n\u003cp\u003eHFC-R507A is a near-azeotropic blend of R125 and R143a (50%\/50%) specifically developed as a high-efficiency, zero-ODP solution for commercial and industrial refrigeration systems. With zero ozone depletion potential and exceptional thermodynamic properties, it has become the industry standard for low and medium-temperature applications where R502 was previously used.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Technical Advantages:\u003cbr\u003e\u003c\/strong\u003eNear-azeotropic performance (\u0026lt;1°C temperature glide) ensures system stability and simplified servicing\u003cbr\u003eSuperior energy efficiency compared to R502 across all operating conditions\u003cbr\u003eA1 safety classification (non-flammable, non-toxic) per ASHRAE Standard 34\u003cbr\u003eOptimized for low-temperature applications down to -50°C evaporating temperature\u003cbr\u003eDirect compatibility with polyol ester (POE) lubricants\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 98.6266%; height: 242.516px;\" height=\"43\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3281px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3281px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3281px;\"\u003e98.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-52.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e159\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e539.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"112\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e99.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"125\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"120\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"158\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e3985\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eCommercial low-temperature refrigeration (supermarket freezers, ice makers)\u003cbr\u003eIndustrial process cooling systems\u003cbr\u003eTransport refrigeration units\u003cbr\u003eBlast freezing equipment\u003cbr\u003eChemical and pharmaceutical cooling processes\u003cbr\u003e\u003c\/p\u003e","brand":"Nycoolmate","offers":[{"title":"Default Title","offer_id":44018987663475,"sku":"HFC-R507A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/26c187da5283f4745edef764fe873f9c_af7a403d-91da-4287-9525-e0dd3f61f669.jpg?v=1763540426"}],"url":"https:\/\/nycoolmate.com\/collections\/hfc.oembed?page=2","provider":"Nycoolmate","version":"1.0","type":"link"}