{"title":"All Refrigerant","description":"","products":[{"product_id":"r407c","title":"R407C","description":"\u003ch3\u003eR407C Refrigerant (HFC Blend for Commercial HVAC\u0026amp;R)\u003c\/h3\u003e\n\u003cp\u003eR407C is a zeotropic HFC blend (R32\/R125\/R134a) with a temperature glide, specifically developed as a replacement for R22. With zero Ozone Depletion Potential (ODP), it offers a cost-effective and reliable solution for both new equipment and retrofit applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 98.6266%; height: 230.173px;\" height=\"43\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5833px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3403px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3403px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3403px;\"\u003e86.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5833px;\"\u003e-43.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5833px;\"\u003e187\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5833px;\"\u003e672.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"112\" style=\"height: 17pt; width: 56.7778%;\"\u003e99.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"125\" style=\"height: 17pt; width: 56.7778%;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"120\" style=\"height: 17pt; width: 56.7778%;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"158\" style=\"height: 17pt; width: 56.7778%;\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5833px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5833px;\"\u003e1770\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eCommercial refrigeration systems\u003cbr\u003eCentralized HVAC plants\u003cbr\u003eChillers \u0026amp; process cooling equipment\u003cbr\u003eIndustrial cold rooms\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003eNot recommended for automotive applications\u003c\/p\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":43981189742707,"sku":"HFC-R407C","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/407C.jpg?v=1761727136"},{"product_id":"r449a","title":"R449A","description":"\u003ch3\u003eR-449A Refrigerant\u003c\/h3\u003e\n\u003cp\u003eR449A is a next-generation HFO\/HFC refrigerant blend (R32 \/ R125 \/ R134a \/ R1234yf) designed to replace high-GWP refrigerants such as R404A and R22 in commercial refrigeration and air conditioning. With a Global Warming Potential (GWP) of ~1397, it reduces climate impact by more than 65% compared to R404A, while delivering excellent cooling efficiency and reliable system performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 98.6266%; height: 242.516px;\" height=\"43\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3281px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3281px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3281px;\"\u003e86.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-50.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e176.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e639.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"112\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e99.90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"125\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"120\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"158\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e\u003cspan\u003eNot Available\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e1397\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003cbr\u003e\u003c\/strong\u003eSupermarket refrigeration (low \u0026amp; medium temperature)\u003cbr\u003eCold storage warehouses \u0026amp; distribution centers\u003cbr\u003eCommercial freezers \u0026amp; display cases\u003cbr\u003eIndustrial refrigeration systems\u003cbr\u003eRetrofit projects for R404A, R507A, and R22 equipment\u003c\/p\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":43981192167539,"sku":"HFO-R449A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/449A.jpg?v=1761727358"},{"product_id":"r22","title":"R22","description":"\u003ch3\u003eR22 Refrigerant (High-Purity HCFC Formulation)\u003c\/h3\u003e\n\u003cp\u003eOur R22 refrigerant delivers reliable performance with minimized environmental impact, featuring an Ozone Depletion Potential (ODP) of 0.0 and non-ozone-depleting characteristics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 98.6266%; height: 230.173px;\" height=\"43\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5833px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3403px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3403px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3403px;\"\u003e86.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5833px;\"\u003e-41.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5833px;\"\u003e205.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5833px;\"\u003e723.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"112\" style=\"height: 17pt; width: 56.7778%;\"\u003e99.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"125\" style=\"height: 17pt; width: 56.7778%;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"120\" style=\"height: 17pt; width: 56.7778%;\"\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"158\" style=\"height: 17pt; width: 56.7778%;\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5833px;\"\u003e0.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5833px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5833px;\"\u003e1810\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eResidential \u0026amp; commercial AC systems\u003cbr\u003eCentral air conditioning units\u003cbr\u003eMobile refrigeration\u003cbr\u003eHeat pump water heaters\u003cbr\u003eDehumidifiers \u0026amp; freeze dryers\u003cbr\u003e\u003c\/p\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":43981196066931,"sku":"HCFC-R22","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/R22.jpg?v=1761726823"},{"product_id":"r404a","title":"R404A","description":"\u003ch3\u003eR404A Refrigerant (High-Performance Solution for Commercial Refrigeration)\u003c\/h3\u003e\n\u003cp\u003eR404A is a colorless, odorless HFC refrigerant suitable for new installations and retrofit applications. With a boiling point of -46.1°C, it delivers reliable performance across critical temperature ranges.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 98.6266%; height: 242.516px;\" height=\"43\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3281px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3281px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3281px;\"\u003e97.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-51.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e162.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e548.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"112\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e99.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"125\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"120\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"158\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e3920\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eSupermarket refrigerated display cases\u003cbr\u003eCommercial cold storage facilities\u003cbr\u003eRefrigerated transport systems\u003cbr\u003eIndustrial ice-making equipment\u003cbr\u003e\u003c\/p\u003e","brand":"My Store","offers":[{"title":"Default Title","offer_id":43981207666803,"sku":"HFC-R404A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/404a.jpg?v=1761726863"},{"product_id":"solstice-ez-flush","title":"Solstice EZ Flush","description":"\u003ch3\u003eSolstice EZ Flush (High-Performance System Cleaning Solvent)\u003c\/h3\u003e\n\u003cp\u003eOur Solstice EZ Flush is a next-generation flushing solvent designed for air conditioning and refrigeration systems. It effectively removes residual oil, moisture, and particulates, ensuring optimal system performance and reliability. Formulated with low toxicity and zero Ozone Depletion Potential (ODP), it is safe for both equipment and the environment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable height=\"43\" style=\"width: 98.6266%; height: 242.375px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3125px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3125px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3125px;\"\u003e130.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eNot Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eNot Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.625px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.625px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd style=\"height: 22.625px; width: 56.7778%;\" width=\"112\" height=\"22\" class=\"et2\"\u003e98\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.625px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.625px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.625px; width: 56.7778%;\" width=\"125\" height=\"22\" class=\"et2\"\u003eNot Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.625px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.625px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.625px; width: 56.7778%;\" width=\"120\" height=\"22\" class=\"et2\"\u003eNot Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.625px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.625px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.625px; width: 56.7778%;\" width=\"158\" height=\"22\" class=\"et2\"\u003eNot Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eNot Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eNot Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWidely implemented in:\u003c\/strong\u003e\u003cbr\u003eResidential \u0026amp; commercial HVAC systems\u003cbr\u003eRefrigeration servicing and retrofitting\u003cbr\u003eMobile air conditioning maintenance\u003cbr\u003eSystem conversions (R22 → HFO blends, R32, R410A)\u003cbr\u003ePreventive cleaning to extend equipment lifespan\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCertified Applications:\u003cbr\u003e\u003c\/strong\u003e• R134a\/R1234yf\/R32 system maintenance\u003cbr\u003e• Compressor replacement protocols (OEM-approved)\u003cbr\u003e• Retrofit flushing (R12\/R22 → R448A\/R449A conversions)\u003cbr\u003e• Chiller oil circuit cleaning (ASHRAE 15 compliant)\u003cbr\u003e• Manufacturing line flushing (ISO 8573-1 Class 0)\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"Nycoolmate","offers":[{"title":"Default Title","offer_id":44018823659635,"sku":"EZ Flush","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/clean-001.jpg?v=1763541235"},{"product_id":"r134a","title":"R134A","description":"\u003ch3\u003eR134A Refrigerant (Next-Generation Eco-Friendly Refrigerant)\u003c\/h3\u003e\n\u003cp\u003eR134A is an environmentally responsible refrigerant with zero Ozone Depletion Potential (ODP), making it non-destructive to the ozone layer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable height=\"43\" style=\"width: 98.6266%; height: 242.438px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3125px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3125px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3125px;\"\u003e102.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-14.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e213.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e588.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6406px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6406px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd style=\"height: 22.6406px; width: 56.7778%;\" width=\"112\" height=\"22\" class=\"et2\"\u003e99.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6406px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6406px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6406px; width: 56.7778%;\" width=\"125\" height=\"22\" class=\"et2\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6406px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6406px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6406px; width: 56.7778%;\" width=\"120\" height=\"22\" class=\"et2\"\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6406px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6406px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6406px; width: 56.7778%;\" width=\"158\" height=\"22\" class=\"et2\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e1430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Advantages:\u003cbr\u003e\u003c\/strong\u003e1. Chlorine-Free \u0026amp; Eco-Safe: Contains no chlorine atoms, eliminating ozone layer damage.\u003cbr\u003e2. Inherent Safety: Features five critical safety properties: non-flammable, non-explosive, non-toxic, non-irritating, and non-corrosive.\u003cbr\u003e3. Enhanced Performance \u0026amp; Compatibility:\u003cbr\u003e   -Delivers superior heat transfer performance compared to R12, significantly reducing refrigerant charge requirements.\u003cbr\u003e   -Maintains similar thermodynamic properties to R12, enabling straightforward system retrofits.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eAutomotive air conditioners (its most common use)\u003cbr\u003eDomestic refrigerators and freezers\u003cbr\u003eCommercial refrigeration systems\u003cbr\u003eStationary building chillers\u003cbr\u003e\u003c\/p\u003e","brand":"Nycoolmate","offers":[{"title":"Default Title","offer_id":44018841518195,"sku":"HFC-R134A-AUTO","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/R134A.jpg?v=1761727308"},{"product_id":"r32","title":"R32","description":"\u003ch3\u003eR32 Refrigerant (Ultra-Low GWP Successor to R410A)\u003c\/h3\u003e\n\u003cp\u003eR32 is a next-generation single-component HFC refrigerant with zero ODP and ultra-low GWP (GWP=675) – 70% lower than R410A. Designed as the sustainable upgrade for R410A systems, it delivers 10-15% higher energy efficiency while enabling 30% refrigerant charge reduction in compliant A2L equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003cbr\u003e\u003c\/strong\u003eMinimal temperature glide (\u0026lt;0.5°C) ensures precise temperature control\u003cbr\u003eA2L safety classification (low flammability) with ISO 5149 compliance\u003cbr\u003eDirect retrofit compatibility with R410A infrastructure (after purge\/flush)\u003cbr\u003eHydrolysis-resistant formulation (moisture ≤0.001%) prevents acid formation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable height=\"43\" style=\"width: 98.6266%; height: 242.438px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3125px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3125px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3125px;\"\u003e50.02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-61.06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e173.12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e846.17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6406px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6406px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd style=\"height: 22.6406px; width: 56.7778%;\" width=\"112\" height=\"22\" class=\"et2\"\u003e99.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6406px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6406px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6406px; width: 56.7778%;\" width=\"125\" height=\"22\" class=\"et2\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6406px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6406px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6406px; width: 56.7778%;\" width=\"120\" height=\"22\" class=\"et2\"\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6406px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6406px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6406px; width: 56.7778%;\" width=\"158\" height=\"22\" class=\"et2\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e675\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eInverter-driven residential AC (Daikin, Mitsubishi Electric)\u003cbr\u003eVRF\/VRV systems with A2L certification\u003cbr\u003eCommercial rooftop units (UL 60335-2-40 compliant)\u003cbr\u003eAir-to-water heat pumps (EN378 compliant)\u003cbr\u003eNew-generation chillers (ASHRAE 34 compatible)\u003cbr\u003e\u003c\/p\u003e","brand":"Nycoolmate","offers":[{"title":"Default Title","offer_id":44018888999027,"sku":"HFC-R32","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/R32.jpg?v=1761727283"},{"product_id":"r407a","title":"R407A","description":"\u003ch3\u003eHFC-R407A Refrigerant (Low-GWP Retrofit Solution for R404A\/R22)\u003c\/h3\u003e\n\u003cp\u003eHFC-R407A is a near-azeotropic HFC blend (R32\/R125\/R134a) designed as a low-glide, drop-in replacement for R404A and R22 in medium-temperature refrigeration systems. With zero ODP and a 30% reduced GWP (GWP≈2100) versus R404A, it complies with global phasedown regulations while maintaining comparable cooling capacity and operational performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Technical Advantages:\u003cbr\u003e\u003c\/strong\u003eOptimized temperature glide (\u0026lt;5°C) minimizes system adjustment requirements\u003cbr\u003eNear-identical operating pressure to R404A simplifies retrofit process\u003cbr\u003ePOE oil compatibility eliminates oil change requirements in most conversions\u003cbr\u003eNon-flammable (ASHRAE A1 classification) for unrestricted application\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable height=\"43\" style=\"width: 98.6266%; height: 242.516px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3281px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3281px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3281px;\"\u003e90.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-49.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e180.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e658.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"112\" height=\"22\" class=\"et2\"\u003e99.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"125\" height=\"22\" class=\"et2\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"120\" height=\"22\" class=\"et2\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"158\" height=\"22\" class=\"et2\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e2110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eMedium-temperature commercial refrigeration (supermarket cases, walk-in coolers)\u003cbr\u003eRetrofitted R404A\/R22 systems (direct drop-in per AHRI Guidelines)\u003cbr\u003eIndustrial process cooling\u003cbr\u003eTransport refrigeration units\u003cbr\u003eIce machines and cold storage units\u003cbr\u003e\u003c\/p\u003e","brand":"Nycoolmate","offers":[{"title":"Default Title","offer_id":44018895061107,"sku":"HFC-R407A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/407A.jpg?v=1761726891"},{"product_id":"r410a","title":"R410A","description":"\u003ch3\u003eR410A Refrigerant (High-Performance HFC Replacement for R22)\u003c\/h3\u003e\n\u003cp\u003eR410A is a near-azeotropic HFC blend with zero ODP (Ozone Depletion Potential), making it an ozone-safe solution. As the industry-standard replacement for R22 in air conditioning systems, it delivers ~5-6% higher refrigeration capacity and operates at higher pressures for improved efficiency.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Technical Advantages:\u003cbr\u003e\u003c\/strong\u003eMinimal temperature glide (\u0026lt;0.2°C) ensures stable system operation\u003cbr\u003ePressure-tolerant formulation maintains physical properties during leakage events\u003cbr\u003eRecharge-friendly: No need to fully evacuate system before replenishing\u003cbr\u003eCorrosion-inhibiting design (moisture ≤0.001%)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 98.6266%; height: 242.516px;\" height=\"43\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3281px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3281px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3281px;\"\u003e72.58\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-60.84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e161.83\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e691.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"112\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e99.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"125\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"120\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"158\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e2088\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eVariable refrigerant flow (VRF) systems\u003cbr\u003eDucted and ductless residential AC\u003cbr\u003eLight commercial rooftop units\u003cbr\u003eAir-to-water heat pumps\u003cbr\u003e\u003c\/p\u003e","brand":"Nycoolmate","offers":[{"title":"Default Title","offer_id":44018902532211,"sku":"HFC-R410A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/410A.jpg?v=1761727252"},{"product_id":"r422b","title":"R422B","description":"\u003ch3\u003eHFC-R422B Refrigerant (Drop-in Replacement for R22 Systems)\u003c\/h3\u003e\n\u003cp\u003eHFC-R422B is a zeotropic HFC blend specifically formulated as a direct drop-in replacement for R22 in existing refrigeration systems. With zero ODP (Ozone Depletion Potential) and a GWP of 2,539, it provides an environmentally improved alternative while maintaining similar operating characteristics to R22, requiring minimal system modifications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Technical Advantages:\u003cbr\u003e\u003c\/strong\u003eNear-identical operating pressure to R22 enables seamless retrofit\u003cbr\u003ePOE oil compatible - can be used with existing mineral oil in many systems\u003cbr\u003eNon-flammable formulation (ASHRAE A1 safety classification)\u003cbr\u003eWide temperature application range (-50°C to +10°C evaporating temperature)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable height=\"43\" style=\"width: 98.6266%; height: 242.516px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3281px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3281px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3281px;\"\u003e108.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-42.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e181.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e574.75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"112\" height=\"22\" class=\"et2\"\u003e99.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"125\" height=\"22\" class=\"et2\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"120\" height=\"22\" class=\"et2\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"158\" height=\"22\" class=\"et2\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e2526\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eDirect expansion refrigeration systems (retrofitted R22 systems)\u003cbr\u003eCommercial refrigeration systems (walk-in coolers, display cases)\u003cbr\u003eIndustrial process cooling systems\u003cbr\u003eTransport refrigeration units\u003cbr\u003eIce making machines\u003cbr\u003e\u003c\/p\u003e","brand":"Nycoolmate","offers":[{"title":"Default Title","offer_id":44018916753523,"sku":"HFC-R422B","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/a3ea2c78f4f24bb87ce2906fd50f295_456ed8fb-fb0d-486d-b790-eb167cf80532.jpg?v=1763540842"},{"product_id":"r422d","title":"R422D","description":"\u003ch3\u003eHFC-R422D Refrigerant (High-Capacity R22 Replacement Solution)\u003c\/h3\u003e\n\u003cp\u003eHFC-R422D is a non-ozone depleting HFC blend specifically formulated as a high-capacity retrofit solution for R22 in commercial refrigeration systems. With zero ODP (Ozone Depletion Potential) and a GWP of 2,729, it provides an environmentally responsible alternative while delivering 5-10% higher cooling capacity compared to R22 in most medium-temperature applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Technical Advantages:\u003cbr\u003e\u003c\/strong\u003eEnhanced cooling capacity reduces compressor runtime and energy consumption\u003cbr\u003eNear-azeotropic behavior (\u0026lt;3°C glide) ensures stable system operation\u003cbr\u003eDirect drop-in compatibility with most R22 systems using POE oil\u003cbr\u003eNon-flammable formulation (ASHRAE A1 safety classification)\u003cbr\u003eWide operating range (-30°C to +10°C evaporating temperature)\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable height=\"43\" style=\"width: 98.6266%; height: 242.438px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3125px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3125px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3125px;\"\u003e109.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-45.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e175.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e565.64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6406px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6406px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd style=\"height: 22.6406px; width: 56.7778%;\" width=\"112\" height=\"22\" class=\"et2\"\u003e99.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6406px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6406px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6406px; width: 56.7778%;\" width=\"125\" height=\"22\" class=\"et2\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6406px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6406px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6406px; width: 56.7778%;\" width=\"120\" height=\"22\" class=\"et2\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6406px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6406px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6406px; width: 56.7778%;\" width=\"158\" height=\"22\" class=\"et2\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e2729\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eSupermarket refrigeration systems (display cases, walk-in coolers)\u003cbr\u003eCommercial cold storage facilities\u003cbr\u003eR22 retrofit applications (direct replacement)\u003cbr\u003eIndustrial process cooling systems\u003cbr\u003eTransport refrigeration units\u003cbr\u003e\u003c\/p\u003e","brand":"Nycoolmate","offers":[{"title":"Default Title","offer_id":44018931138675,"sku":"HFC-R422D","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/358367c0581e0cbfc9e6192e1071f7d_ceda68a6-4ab2-4134-aac6-52d237c1b97e.jpg?v=1763540708"},{"product_id":"r427a","title":"R427A","description":"\u003ch3\u003eHFC-R427A Refrigerant (Zero ODP Drop-in Replacement for R22 Systems)\u003c\/h3\u003e\n\u003cp\u003eHFC-R427A is a non-ozone depleting, near-azeotropic refrigerant blend designed as a direct retrofit solution for R22 in existing air conditioning and refrigeration systems. With zero ODP (Ozone Depletion Potential) and a significantly reduced GWP of 2,130 (compared to R22's GWP of 1,810), it provides an environmentally responsible alternative that requires minimal system modifications while maintaining comparable performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Technical Advantages:\u003cbr\u003e\u003c\/strong\u003eExcellent capacity matching (95-100% of R22 capacity) minimizes system reengineering\u003cbr\u003eLow temperature glide (\u0026lt;4°C) ensures stable operation and easy troubleshooting\u003cbr\u003eDirect drop-in replacement for most R22 systems with POE lubricants\u003cbr\u003eA1 safety classification (non-flammable, non-toxic) per ASHRAE Standard 34\u003cbr\u003eGood material compatibility with common metals and elastomers\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 98.6266%; height: 242.516px;\" height=\"43\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3281px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3281px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3281px;\"\u003e90.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-44.86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e188.24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e594.65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"112\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e99.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"125\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"120\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"158\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e2107\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eR22 retrofit in air conditioning systems (residential and commercial)\u003cbr\u003eCommercial refrigeration systems (walk-in coolers, display cases)\u003cbr\u003eIndustrial cooling processes\u003cbr\u003eHeat pump systems\u003cbr\u003eTransport refrigeration\u003cbr\u003e\u003c\/p\u003e","brand":"Nycoolmate","offers":[{"title":"Default Title","offer_id":44018936873075,"sku":"HFC-R427A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/a3b5a57f519e70227af39ea7ea8a090_b93dcd23-027b-4d22-aa20-9991a0919fc6.jpg?v=1763540617"},{"product_id":"r438a","title":"R438A","description":"\u003ch3\u003eHFC-R438A Refrigerant (MO29™; Long-Term R22 Retrofit Solution)\u003c\/h3\u003e\n\u003cp\u003eHFC-R438A is a non-ozone depleting zeotropic blend specifically developed as a near-drop-in replacement for R22 in existing air conditioning and refrigeration systems. With zero ODP and a moderate GWP of 2,264, it offers a balanced solution for phasing out R22 without major system modifications. Its composition is designed to closely match R22's operating pressure and capacity while maintaining compatibility with both mineral oil and POE lubricants.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Technical Advantages:\u003cbr\u003e\u003c\/strong\u003eExcellent pressure and capacity match to R22 (within ±5%)\u003cbr\u003eUnique lubricant compatibility - works with existing mineral oil or POE\u003cbr\u003eLow temperature glide (\u0026lt;7°C) for stable system operation\u003cbr\u003eA1 safety classification (non-flammable) per ASHRAE Standard 34\u003cbr\u003eReduced discharge temperature extends compressor life\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable height=\"43\" style=\"width: 98.6266%; height: 242.516px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3281px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3281px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3281px;\"\u003e99.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-44.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e185.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e623.66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"112\" height=\"22\" class=\"et2\"\u003e99.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"125\" height=\"22\" class=\"et2\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"120\" height=\"22\" class=\"et2\"\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"158\" height=\"22\" class=\"et2\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e2037\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eDirect R22 replacement in AC systems (residential and commercial)\u003cbr\u003eCommercial refrigeration retrofit (supermarkets, cold storage)\u003cbr\u003eIndustrial process cooling systems\u003cbr\u003eHeat pumps and chillers\u003cbr\u003eTransport refrigeration units\u003cbr\u003e\u003c\/p\u003e","brand":"Nycoolmate","offers":[{"title":"Default Title","offer_id":44018945556595,"sku":"HFC-R438A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/dd7c65c81af00db4aa96de9b1453460_e1920451-c45c-4c98-ada8-02e184d1d988.jpg?v=1763540545"},{"product_id":"r453a","title":"R453A","description":"\u003ch3\u003eHFC-R453A Refrigerant (R454B; Low-GWP R410A Alternative with A2L Classification)\u003c\/h3\u003e\n\u003cp\u003eHFC-R453A is a mildly flammable, low-global warming potential (GWP) refrigerant blend designed as a next-generation alternative to R410A in new air conditioning and heat pump applications. With a significantly reduced GWP of 465 (approximately 78% lower than R410A) and zero ODP, it offers an environmentally sustainable solution aligned with global regulatory phase-down schedules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Technical Advantages:\u003cbr\u003e\u003c\/strong\u003eUltra-low GWP (465) meets stringent environmental regulations\u003cbr\u003eSimilar cooling capacity to R410A (within -5% to +5% range)\u003cbr\u003eLower discharge temperatures enhance compressor reliability\u003cbr\u003eMildly flammable (A2L) classification with proven safety track record\u003cbr\u003eReduced direct emissions impact compared to HFC alternatives\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 98.6266%; height: 242.516px;\" height=\"43\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3281px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3281px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3281px;\"\u003e88.78\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-43.96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e191.48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e665.59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"112\" style=\"height: 22.6562px; width: 56.7778%;\"\u003eNot Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"125\" style=\"height: 22.6562px; width: 56.7778%;\"\u003eNot Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"120\" style=\"height: 22.6562px; width: 56.7778%;\"\u003eNot Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"158\" style=\"height: 22.6562px; width: 56.7778%;\"\u003eNot Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e1486\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eNew residential and commercial AC systems\u003cbr\u003eAir-to-water heat pumps\u003cbr\u003eVariable refrigerant flow (VRF) systems\u003cbr\u003eRooftop packaged units\u003cbr\u003eSpecialty cooling applications\u003cbr\u003e\u003c\/p\u003e","brand":"Nycoolmate","offers":[{"title":"Default Title","offer_id":44018958565491,"sku":"HFC-R453A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/901d8b2410e712396ef77b454998d5a_de2a058c-127b-4f32-b91d-1417a75d3ed5.jpg?v=1763540479"},{"product_id":"r507a","title":"R507A","description":"\u003ch3\u003eHFC-R507A Refrigerant (High-Performance Azeotropic Replacement for R502)\u003c\/h3\u003e\n\u003cp\u003eHFC-R507A is a near-azeotropic blend of R125 and R143a (50%\/50%) specifically developed as a high-efficiency, zero-ODP solution for commercial and industrial refrigeration systems. With zero ozone depletion potential and exceptional thermodynamic properties, it has become the industry standard for low and medium-temperature applications where R502 was previously used.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Technical Advantages:\u003cbr\u003e\u003c\/strong\u003eNear-azeotropic performance (\u0026lt;1°C temperature glide) ensures system stability and simplified servicing\u003cbr\u003eSuperior energy efficiency compared to R502 across all operating conditions\u003cbr\u003eA1 safety classification (non-flammable, non-toxic) per ASHRAE Standard 34\u003cbr\u003eOptimized for low-temperature applications down to -50°C evaporating temperature\u003cbr\u003eDirect compatibility with polyol ester (POE) lubricants\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 98.6266%; height: 242.516px;\" height=\"43\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3281px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3281px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3281px;\"\u003e98.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-52.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e159\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e539.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"112\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e99.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"125\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"120\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"158\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e3985\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eCommercial low-temperature refrigeration (supermarket freezers, ice makers)\u003cbr\u003eIndustrial process cooling systems\u003cbr\u003eTransport refrigeration units\u003cbr\u003eBlast freezing equipment\u003cbr\u003eChemical and pharmaceutical cooling processes\u003cbr\u003e\u003c\/p\u003e","brand":"Nycoolmate","offers":[{"title":"Default Title","offer_id":44018987663475,"sku":"HFC-R507A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/26c187da5283f4745edef764fe873f9c_af7a403d-91da-4287-9525-e0dd3f61f669.jpg?v=1763540426"},{"product_id":"1234yf","title":"1234YF","description":"\u003ch3\u003eHFO-1234yf Refrigerant (Low-GWP HFC-134a Replacement for Automotive A\/C)\u003c\/h3\u003e\n\u003cp\u003eHFO-1234yf is a hydrofluoroolefin refrigerant with an ultra-low Global Warming Potential (GWP ≈ 4), making it the environmentally preferred replacement for HFC-134a in mobile air conditioning (MAC) systems. With zero Ozone Depletion Potential (ODP), it provides comparable thermodynamic performance to R134a while meeting stringent global environmental regulations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Technical Advantages:\u003cbr\u003e\u003c\/strong\u003eUltra-low GWP (~4) meets EU F-Gas and U.S. EPA SNAP compliance requirements\u003cbr\u003eComparable cooling capacity and efficiency to HFC-134a\u003cbr\u003eChemically stable with lubricants and system materials\u003cbr\u003eLower flammability classification (ASHRAE A2L) for safe system integration\u003cbr\u003eDrop-in compatibility for next-generation automotive A\/C platforms\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 98.6266%; height: 242.516px;\" height=\"43\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3281px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3281px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3281px;\"\u003e114\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e202.46\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e490.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"112\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e99.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"125\" style=\"height: 22.6562px; width: 56.7778%;\"\u003eNot Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"120\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"158\" style=\"height: 22.6562px; width: 56.7778%;\"\u003eNot Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eAutomotive air conditioning (MAC) systems\u003cbr\u003eHybrid and electric vehicle cooling loops\u003cbr\u003eLight commercial vehicle climate control\u003cbr\u003eFuture-oriented HVAC\/R applications requiring low-GWP refrigerants\u003cbr\u003e\u003c\/p\u003e","brand":"Nycoolmate","offers":[{"title":"Default Title","offer_id":44019030065267,"sku":"HFO-1234YF","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/1234YF.jpg?v=1761727375"},{"product_id":"r421a","title":"R421A","description":"\u003ch3\u003eR421A Refrigerant (Non-Ozone-Depleting HFC Replacement for R22)\u003c\/h3\u003e\n\u003cp\u003eR421A is a high-efficiency HFC refrigerant blend (R125 \/ R134a) specifically developed as a direct replacement for R22 in residential and commercial air conditioning and refrigeration systems. With zero Ozone Depletion Potential (ODP) and significantly lower discharge temperatures, R421A extends compressor life while maintaining reliable cooling performance. Importantly, it is compatible with existing mineral, alkylbenzene, and POE oils, eliminating the need for costly lubricant changes during retrofits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Technical Advantages:\u003cbr\u003e\u003c\/strong\u003eZero ODP for environmentally responsible cooling\u003cbr\u003eNo oil change required when replacing R22\u003cbr\u003eLower discharge temperature reduces compressor stress\u003cbr\u003eExcellent energy efficiency and cooling capacity\u003cbr\u003eLow glide (\u0026lt;1°C) ensures stable system performance\u003cbr\u003eProven retrofit solution for existing R22 systems\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable height=\"43\" style=\"width: 98.6266%; height: 242.516px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3281px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3281px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3281px;\"\u003e111.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-41.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e181\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e568.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"112\" height=\"22\" class=\"et2\"\u003e99.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"125\" height=\"22\" class=\"et2\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"120\" height=\"22\" class=\"et2\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"158\" height=\"22\" class=\"et2\"\u003eNot Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e2600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eResidential \u0026amp; commercial air conditioning (ducted \u0026amp; ductless)\u003cbr\u003ePackaged rooftop units\u003cbr\u003eRefrigerated display cases \u0026amp; cold storage\u003cbr\u003eHeat pumps and split systems\u003cbr\u003eRetrofit projects for R22 phase-out compliance\u003cbr\u003e\u003c\/p\u003e","brand":"Nycoolmate","offers":[{"title":"Default Title","offer_id":44019042812019,"sku":"HFO-R421A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/a5b89b980e74a5ba4e487b609bb4196_a4ab58db-01ed-4093-96c5-d129bf72d9e8.jpg?v=1763539697"},{"product_id":"r448a","title":"R448A","description":"\u003ch3\u003eR448A Refrigerant (Next-Generation Low-GWP Replacement for R404A \u0026amp; R22)\u003c\/h3\u003e\n\u003cp\u003eR448A is a non-ozone-depleting HFO\/HFC blend (R32 \/ R125 \/ R134a \/ R1234yf \/ R1234ze) designed as a sustainable alternative to R404A and R22 in commercial refrigeration and air conditioning. With a Global Warming Potential (GWP) of ~1273, R448A offers more than a 65% reduction in GWP compared to R404A, while maintaining excellent energy efficiency and refrigeration capacity. Its low temperature glide and reliable system compatibility make it an ideal choice for both new equipment and retrofit applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Technical Advantages:\u003cbr\u003e\u003c\/strong\u003eZero ODP and significantly reduced GWP (~1273 vs. ~3922 for R404A)\u003cbr\u003eHigher energy efficiency compared to R404A \u0026amp; R507A\u003cbr\u003eLow temperature glide (~6 K) ensures stable and predictable performance\u003cbr\u003eCompatible with existing POE lubricants for seamless retrofits\u003cbr\u003eApproved by major compressor and equipment manufacturers\u003cbr\u003eLower discharge temperature extends compressor lifespan\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 98.6266%; height: 242.516px;\" height=\"43\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3281px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3281px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3281px;\"\u003e86.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e180.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e666.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"112\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e99.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"125\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"120\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"158\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e1387\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eCommercial refrigeration (supermarkets, display cases, cold rooms)\u003cbr\u003eIndustrial food processing and storage facilities\u003cbr\u003eTransport refrigeration systems\u003cbr\u003eAir-to-water and air-to-air heat pumps\u003cbr\u003eRetrofit projects for R404A, R507A, and R22 phase-out compliance\u003cbr\u003e\u003c\/p\u003e","brand":"Nycoolmate","offers":[{"title":"Default Title","offer_id":44019049496691,"sku":"HFO-R448A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/448A_579097b5-a908-4f03-98fe-c9d105a21406.jpg?v=1763539596"},{"product_id":"r452a","title":"R452A","description":"\u003ch3\u003eR452A Refrigerant (Low-GWP HFO Blend Replacement for R404A \u0026amp; R507A)\u003c\/h3\u003e\n\u003cp\u003eR452A is a next-generation HFO\/HFC refrigerant blend (R32 \/ R125 \/ R1234yf) developed to replace high-GWP refrigerants such as R404A and R507A in commercial refrigeration and transport applications. With a Global Warming Potential (GWP) of ~2140, it provides a 45% reduction in GWP compared to R404A, while offering nearly identical cooling performance and efficiency, making it a strong candidate for direct system retrofits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Technical Advantages:\u003cbr\u003e\u003c\/strong\u003eZero ODP with significantly reduced GWP (~2140 vs. ~3922 for R404A)\u003cbr\u003eComparable capacity and efficiency to R404A\/R507A for easy retrofit\u003cbr\u003eLower discharge temperature extends compressor service life\u003cbr\u003eCompatible with existing POE lubricants—no oil change required\u003cbr\u003eApproved by major compressor and transport refrigeration OEMs\u003cbr\u003eModerate glide (~2 K) ensures stable and predictable operation\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 98.6266%; height: 242.516px;\" height=\"43\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3281px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3281px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3281px;\"\u003e103.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-52.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e166.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e580.12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"112\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e99.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"125\" style=\"height: 22.6562px; width: 56.7778%;\"\u003eNot Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"120\" style=\"height: 22.6562px; width: 56.7778%;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd class=\"et2\" height=\"22\" width=\"158\" style=\"height: 22.6562px; width: 56.7778%;\"\u003eNot Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e2140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eTransport refrigeration (truck \u0026amp; trailer units)\u003cbr\u003eCommercial freezers and refrigerated display cases\u003cbr\u003eCold storage and food distribution facilities\u003cbr\u003eRetrofit projects replacing R404A and R507A\u003cbr\u003eMedium- and low-temperature commercial refrigeration\u003cbr\u003e\u003c\/p\u003e","brand":"Nycoolmate","offers":[{"title":"Default Title","offer_id":44019054870643,"sku":"HFO-R452A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/8b15db02dc1896f9c2e493c9ca67be1_bc260f43-100e-437e-9dd5-b2f659772e26.jpg?v=1763539536"},{"product_id":"r513a","title":"R513A","description":"\u003ch3\u003eR513A Refrigerant (Low-GWP HFO Blend Replacement for R134a)\u003c\/h3\u003e\n\u003cp\u003eR513A is an azeotropic HFO\/HFC blend (R1234yf \/ R134a, 56% \/ 44%) specifically designed as a low-GWP replacement for R134a in medium-temperature refrigeration and air conditioning. With a Global Warming Potential (GWP) of ~573, it delivers a 56% reduction in GWP compared to R134a (~1430), while offering nearly identical performance characteristics, making it ideal for both new equipment and retrofit projects.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Technical Advantages:\u003cbr\u003e\u003c\/strong\u003eZero ODP and significantly reduced GWP (~573) for regulatory compliance\u003cbr\u003eSimilar cooling capacity and efficiency to R134a\u003cbr\u003eAzeotropic formulation ensures minimal glide (\u0026lt;0.5 K) and stable performance\u003cbr\u003eCompatible with existing POE lubricants—no oil change required\u003cbr\u003eNon-flammable (ASHRAE A1 classification) for safe system use\u003cbr\u003eBackward compatible with most R134a system designs\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eKey Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable height=\"43\" style=\"width: 98.6266%; height: 242.516px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 34.3281px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 34.3281px;\"\u003eMolecular Weight\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 34.3281px;\"\u003e108.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eBoiling Point (1atm,°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e-20.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Temperature (°F)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e173.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eCritical Pressure (psia)\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e546.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003ePurity % ≥\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"112\" height=\"22\" class=\"et2\"\u003e99.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eMoisture ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"125\" height=\"22\" class=\"et2\"\u003eNot Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eAcidity ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"120\" height=\"22\" class=\"et2\"\u003eNot Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 22.6562px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 22.6562px;\"\u003eVapor Residue ppm ≤\u003c\/td\u003e\n\u003ctd style=\"height: 22.6562px; width: 56.7778%;\" width=\"158\" height=\"22\" class=\"et2\"\u003eNot Available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eOzone Depletion Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 43.1134%; height: 19.5938px;\"\u003eGlobal Warming Potential\u003c\/td\u003e\n\u003ctd style=\"width: 56.7778%; height: 19.5938px;\"\u003e573\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry-Standard Applications:\u003c\/strong\u003e\u003cbr\u003eCommercial refrigeration (medium-temperature systems)\u003cbr\u003eChillers and air-cooled liquid coolers\u003cbr\u003eStationary air conditioning systems\u003cbr\u003eFood service equipment (beverage coolers, vending machines)\u003cbr\u003eRetrofit projects replacing R134a\u003cbr\u003e\u003c\/p\u003e","brand":"Nycoolmate","offers":[{"title":"Default Title","offer_id":44019061915763,"sku":"HFO-R513A","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0675\/9206\/1043\/files\/82c94ad1fe9ca2a63cbddf65022c1bf_116d56c3-06a5-4ebb-a282-569acc66d710.jpg?v=1763539496"}],"url":"https:\/\/nycoolmate.com\/collections\/all-refrigerant.oembed?page=2","provider":"Nycoolmate","version":"1.0","type":"link"}